SE-701 Series

Ground-Fault Monitor

SE-701 Updated Copy

We're here to help

Talk to an expert today.
Our friendly team of highly trained specialists will quickly assist you.

Get a quote technical support 1300 387 326

Description

The SE-701 is a microprocessor-based ground-fault relay for resistanceand solidly-grounded systems. In addition to common systems, it is uniquely suited for use on systems with significant harmonic content. The SE-701 can provide main-plant protection, feeder-level protection, or individual-load protection. Proper current transformer selection provides the desired pickup range. The output contacts can be connected for use in protective tripping circuits or in alarm indication circuits. The analog output can be used with a PLC or a meter.


Features & Benefits

  • Adjustable pickup (1-99%)

    Trip setting based on input CT primary, allows use with any CT. Minimum 50 mA with EFCT Series

  • Adjustable time delay (50 ms-2.5 s)

    Adjustable trip delay allows quick protection and system coordination
  • Output contacts

    Form A and Form B ground-fault output contacts for operation of separate annunciation and trip circuits

  • Analog output (0-5 V)

    Allows for connecting an optional meter (PGA-0500) or a control system

  • CT-Loop monitoring

    Alarms when CT is not connected

  • Selectable DFT or peak detection filtering

    Compatible with variable-speed drives

  • Harmonic filtering

    Eliminates nuisance tripping

  • Non-volatile trip memory

    Retains trip state while de-energized to simplify troubleshooting

  • Microprocessor based

    No calibration required, saves on maintenance cost

  • Universal power supply

    Allows operation in application where one side of PT is faulted, provides flexibility for numerous applications


Datasheets & Manuals

SE-701 Datasheet

SE-701 Manual

Protection Relays Line Card

SE-EFVC (Voltage Clamp) Datasheet

Specifications

  • IEEE Device Numbers: Ground fault (50G/N, 51G/N)
  • Input Voltage: See ordering information
  • Dimensions: H 75 mm (3.0"); W 55 mm (2.2"); D 115 mm (4.5")
  • Trip Level Settings: 1-99% CT-Primary Rating
  • Trip Time Settings: 0.05-2.5 s
  • Contact Operating Mode: Selectable fail-safe or non-fail-safe
  • Harmonic Filtering: Standard feature
  • Test Button: Standard feature
  • Reset Button: Standard feature
  • CT-Loop Monitoring: Standard feature
  • Output Contacts: Isolated Form A and Form B
  • Approvals: CSA certified, UL Listed (E340889), CE (European Union), C-Tick (Australian)
  • Analog Output: 0-5 V
  • Conformally coated: Consult factory
  • Warranty: 5 years
  • Mounting: DIN, Surface (standard) Panel (with PMA-55 or PMA-60 adapter) 


Ordering Information

ORDERING NUMBER
CONTROL POWER
SE-701-OU 120/240
VAC/VDC
SE-701-OD 12/24
VDC
SE-701-OT 48
VDC
SE-701-O3 24
VAC


ACCESSORIES
REQUIREMENT
Current Transformer
Required
PGA-0500
Optional
PMA-55, PMA-60
Optional
SE-EFVC Voltage Clamp
Optional


Accessories

Ground-Fault Current Transformer
Required current transformer model depends on application. We offer a variety of sensitive CTs with 5- and 30-A primaries.

PGA-0500 Analog % Current Meter
Optional panel-mounted analog meter displays ground-fault current as a percentage of the CT primary rating.

Featured Case Study

Cliff Head Off-Shore Oil Rig

The Cliff Head Oil Field Platform (Cliff Head) in located in the Perth Basin about 270 kilometres north of Perth and 12 kilometres off the coast of Dongara in Western Australia. Cliff Head resides in the Production License WA-31-L which covers 72km², and the oil field covers 6km² in the Commonwealth Exploration Permit WA-286-P. Cliff Head is located at a water depth of 15-20 metres and is an integral part of the region’s oil drilling infrastructure.

We're here to help

Talk to an expert today.
Our friendly team of highly trained specialists will quickly assist you.

Get a quote technical support 1300 387 326

We promise to respond within 4 business hours (AEST).

Or you will receive $100 off your next purchase. Read how it works.

Ribbon with dollar sign drawn in bold orange lines

Premium brands

Our brands are carefully selected and have a great track record of quality, reliability and safety.

Icon for transport shows drawing of truck in motion drawn in orange bold lines.

Years of experience

Since being established in 1996, our company has been synonymous with great customer service.

Happy face with bangs logo drawn in thick orange line.

Customers served daily

Fuseco has strong relationships with many clients from a wide range of industries.

Clock showing 4 o'clock drawn in thick orange line.

Reply in 4 Hours

You will receive $100 off your next purchase if we do not reply within 4 business hours (AEST).

Related Resources

Can your facility cope with days, weeks, or even months of downtime as you rebuild damaged infrastructure resulting from an arc flash incident?
Fuseco supplies cutting-edge relay solutions from Littelfuse.
The Dugald River Zinc Mine, located in the north-west of Cloncurry in Northern Queensland, and owned by MMG, had Neutral Earthing Resistor’s installed on site and they were doing annual periodic maintenance checks to verify NER resistance and integrity during shutdowns.
A motor protection relay is designed to help protect motors from overloads, jams, phase loss or unbalance, heat, heavy start-ups or excessive operational cycles.
Clever yet very simple and cost-effective steps can be taken today, to improve the electrical safety of old switchboards in use across the country, lacking modern protection against arc-fault events.
The Littelfuse EL731 series is a new and sensitive Earth Leakage Technology – the first of its kind to offer complete coverage of all frequencies from 0(DC) to 6,000Hz, including DC earth leakage typical for VSD applications.
Had this relay not been there, they were looking at between $800,000 to $1 million in damages.
A Neutral Earthing Resistor (NER) plays an important role in an electrical environment and is one of the most effective ways to maximise personnel safety. Continual monitoring is imperative to detect resistor failure with or without an earth fault present.
The MP8000 dramatically increases motor protection, resulting in longer motor life plus reduced downtime and repair costs.
Protect your People. Protect your Equipment.
This white paper reviews charging current, ground-fault detection, and ground-fault coordination.
A Valuable Detection Solution for Photovoltaic Systems.
Littelfuse Protection Relay and Arc-Flash FAQ
Littelfuse White Paper -Key Considerations for selecting-Arc-Flash
Littelfuse Protection Relays AF0100 Generator Application Guide
Littelfuse PGR-8800 Application Guide
Littelfuse AF-0500 Application Guide
Littelfuse Diagram -Protect Your Wind Turbine From Arc-Flash hazards
A new approach to mining earth leakage protection with medium voltage drives

our brand portfolio

Littelfuse logo in green on white background

Top FAQs

A protection relay is a device that receives inputs typically from current transformers CT’s (but can be other sources) and then compares these inputs to set levels. If these inputs exceed the set levels a protection relay can then provide that information via display or indication, feed that information to other electronic control devices or it can be connected to a circuit breaker to isolate power.

Yes, currently Fuseco can offer both earth leakage and NER relays that are compliant to AS2081:2011. The relay manufacturer (Littelfuse) is also currently in the final stages of development for an AS2081:2011 compliant continuity relay that we expect to release in the near term.

An arc fault is a type of electrical fault that results from the breakdown of an insulating medium between two conductors where the energy is enough to sustain an arc across the insulator (often air) and can cause extreme amounts of light (arc flash), immense heat upwards of 19,000 degrees, and a resulting explosive pressure wave (arc blast). By using a relay that has optical sensors we can detect the flash of light the emanates from an Arc Flash and within 1 msec send a signal to a breaker to interrupt power. Because of the immense energy being released by an Arc Flash reaction time is critical. It can be seen on the graph that with a relay reaction time of only 1 msec (+ circuit breaker reaction time) we can interrupt power before the Arc Flash can result in critical damage.

An arc-flash happens when electric current flows through an air gap between conductors. There are several ways this can happen but the most common occurrence is when conductor insulation is worn or broken down.

The most important aspects of arc-flash relays are:


  • reaction time
  • trip reliability
  • ease of installation
  • sensor flexibility
  • software
  • sensor design
  • avoidance of nuisance tripping
  • scalability


To gain a deeper understanding of which features to consider when selecting an arc-flash relay please refer to the downloadable application guides.

Arc-flash relays are a necessary component in an electrical cabinet because they reduce the amount of incident energy in the system. While an arc-flash relay cannot prevent an arc flash from happening, it will protect critical assets and workers’ safety by reducing the severity of the flash. An arc-flash relay is an integral part of an arc-flash protection scheme that can minimize damage, and save money, time, and lives.

Three phase power systems are most often solidly earthed, however by using a Neutral Earthing Resistor (NER) a power system can be resistance earthed. This is done so that if an earth fault were to occur the amount of fault current will be limited by the NER resistance. One potential problem with a resistance earthed system is; what happens if the NER goes open circuit due to damage? If this were to happen the power system has now changed from a resistance earthed system to a system with no earth reference (floating). Now the NER is no longer restricting the amount of fault current and other devices that rely on an earth reference in order to operate, cannot do so. By using a NER monitoring relay the resistance and integrity of a NER can be continually monitored to detect for any variance in the NER resistance or integrity.

An earth fault can occur as a result of inadvertent contact between and energized conductor and earth or equipment frame. There can also be earth leakage from a system without “inadvertent contact”. This type of fault can be called capacitive earth leakage and it is caused by a capacitive effect between a high power conductor and earth. Small amount of earth leakage current can occur as a result of this capacitive effect. Whether it is smaller amounts current from capacitive earth leakage or larger amounts of current from direct inadvertent contact an earth leakage relay can detect this fault current. In all electrical circuits, current returns to its source. An earth fault relay can use a zero sequence CT to monitor phase current to ensure that all current coming from the source returns on those same conductors or it can monitor current in the connection between transformer neutral and earth. By either method the earth leakage relay detect any lost current to earth.

Applicable Industries

Hi Tim, just wanted to thank you and the Fuseco team for your help. You've managed to help us solve some nagging issues here and the Littelfuse SE-330AU relay installation has saved us a lot of time. Thanks!

Mark Sherman

PGS Silver, Queensland

Just wanted to send a note of thanks to you guys. When it comes to relays, your advice & service is high level & appreciated. Cheers.

Jesse Marshall

Newcrest WA

The Littelfuse SE-701 & the CT's are functioning well. Thanks guys, really appreciate your help. Good to work with people you can rely on.

Cliff Peligro

Alpha Coal, Queensland

Technical Support

Our experts are all pre-eminent leaders in electrical products who provide excellent support in their areas of expertise.

Technical support

Talk to an expert

Our friendly team are highly trained product experts who really enjoy helping customers find what they need.

1300 387 326

call 1300 387 326

Enquire by email

We promise to respond within 4 business hours (AEST) or you will receive $100 off your next purchase.

Enquire now